Single phase, Single phase zero crossing, Two-wire three-phase zero crossing (SP, SZ, TZ)
Connector Pin Connector
No.
Description Notes
TB-01 FS  Detection of the fuse burn down  Do not connect
TB-02 M  +5VDC  Only for this control board, not for other use
 positive control signal input.
TB-03 +  Positive control signal input  The default setting is 4~20mA when the
 sticker is not marked.
TB-04 -  Standard and analog signal voltage
TB-05 E3  Connected to the VR 3rd pin of the outside potentiometer  Adjustable output 0~100%, Please eliminate
 the shorted copper wire between E3 and E2
 when using the outside potentiometer with
 VR. (2~10KΩ)
TB-06 E2  Connected to the VR 2rd pin of the outside potentiometer
TB-07 E1  Connected to the VR 1st pin of the outside potentiometer
TB-08 NC  Alarm connector output (normal close) Connector capacity 227VAC 2A.
TB-09 COM  Alarm connector output (Common point) 125VAC 2A.
TB-10 NO  Alarm connector output (normal open) 30VAC 2A.
TB-11 AC1  Auxiliary power source  Please refer to the stick for the auxiliary
 power and voltage.
TB-12 AC2

Three-wire three-phase angle, Three-wire three-phase zero crossing (TP, ZZ)
Connector Pin Connector
No.
Description Notes
TB-01  Empty pin  Do not connect
TB-02 M  +5VDC  Only for this control board, not for other use
 positive control signal input.
TB-03 +  Positive control signal input  The default setting is 4~20mA when the
 sticker is not marked.
TB-04 -  Standard and signal voltage
TB-05 E3  Connected to the VR 3rd pin of the outside potentiometer  Adjustable output 0~100%, Please eliminate
 the shorted copper wire between E3 and E2
 when using the outside potentiometer with
 VR. (2~10KΩ)
TB-06 E2  Connected to the VR 2rd pin of the outside potentiometer
TB-07 E1  Connected to the VR 1st pin of the outside potentiometer
TB-08 NC  Alarm connector output (normal close) Connector capacity 227VAC 2A.
TB-09 COM  Alarm connector output (Common point) 125VAC 2A.
TB-10 NO  Alarm connector output (normal open) 30VAC 2A.
TB-11 AC1  Auxiliary power source  Please refer to the stick for the auxiliary
 power and voltage.
TB-12 AC2

Applicable high-speed fuse for the power regulator
Rated current 30A 45A 60A 80A 100A
Fuse 40FE 63FE 80FE 100FE 660GH-125
Brand Bussmann Bussmann Bussmann Bussmann HINODE
Rated current 125A 150A 180A 230A 300A
Fuse 80FE*2 100FE*2 660GH-125*2 250FM 315FM
Brand Bussmann Bussmann HINODE Bussmann Bussmann
Rated current 380A 450A 580A 720A
Fuse 660GH-400 250FM*2 315FM*2 660GH-400*2
Brand Bussmann Bussmann Bussmann HINODE


A ONE UNION CO., LTD.
5F, No. 99, Sec. 3, Nangang Road., Nangang District, Taipai City 115 63, Taiwan
TEL : +886-2-27882828  FAX : +886-2-27882727
URL : www.aone.com.tw