THYRISTOR
POWER REGULATOR |
|
|
Mounting
Dimensions |
|
Product
Features: |
|
◎The SCR unit attached with high speed fuse in
order to prevent the damage of SCR due to the shortage current (di/dt).
◎The unit is packagecd onstruction with less dimension, easy for
installation and wiring
◎The causes of malfuntion can be indicated by individual LED
lamp, easy for trouble shooting.
◎Less non-linearity output provides accurate control of
temperature.
◎High quality and high technical productions with no electrical
interference.
|
Operation
Enviroment:
◎Ambient temperature:-10~45℃,Relative
humidity: Max 90% |
Installation:
◎The SCR unit will produce heat itself
during operation, piease errect it
upward accrding to the instruction.
◎The
panel must be upward ventilated for hot air. we recommand
mountiong a ventilating fan in the control panel.
◎Do
nor install the unit in the space with high temperature and poor
ventilating, Do not operate the unit exceed 70% of rated
output in
case of above mentioned poor ambient conditions. |
|
Load
Test:
◎The
SCR unit will not well funtioned in case of less output load(0.6 Amp).
Please connect the load at least 0.6 Amp. |
Comparation
of control mode and output wave: |
|
|
|
LED
lamp indication and trouble shooting:
| Pos.No |
Color |
Indicating condition |
Causes of malfunction |
Treament and trouble shooting |
PL
(L1)
|
Green |
No indication of power
supply lamp
Lamp lighting means
normal
|
@No power of Aux. source.
@Malfuntion on PCB board.
@Over temperature of SCR. |
@Check the Aux.power supply.
@Repair or replace the PCB board.
@Check the SER temperature. |
IN
(L2)
|
Green |
No indication of input lamp
Lamp lighting means normal
|
@No output signal from TIC
@Output signal from TIC is
reverse.
@Max value of internal output
or External VR is zero setted.
|
@Check the output signal of TIC.
@Reverse the connect wiring of
TIC.
@Check the setting of internal
and external VR output. |
OUT
(L3)
|
Red |
No indication of output lamp.
Phase angle control--
lamp lighting means normal
Aero crossing control--
lamp blinks means normal
|
@No output signal from TIC or
reverse the connecting of
output signal.
@Lamp IN lighting and lamp
OUT no indication.
@Lamp OUT lighting but no
current output.
|
@Check the lamp IN,No indication
means no output signal from
TIC or reverse wired.
@Repair or replace the PCB board
in case of the nalfunction from
the board.
@Check main power supply or
fuse. |
ERR
(L4)
|
Yellow |
Over-temp of SCR lamp light
Lamp lighting means SCR
over temp
|
@Malfunction or dirt blocking
on the ventilation fan.
@High ambient temperature or
poor ventilation. |
@Replace or clean the dirt of the
impeller.
@Improve the ventilation
condition. |
|